Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Endo, Tomohiro*; Noguchi, Akihiro*; Yamamoto, Akio*; Tada, Kenichi
Transactions of the American Nuclear Society, 124(1), p.184 - 187, 2021/06
This study confirmed that the sensitivity analysis of the alpha-eigenvalue can be carried even for non-neutron multiplication systems such as water-only systems. The preliminary results of nuclear data-induced uncertainties of alpha-eigenvalue were smaller than the differences between numerical and experimental results of alpha-eigenvalue. For further investigation, it is necessary to reconsider the experimental bias and the nuclear data-induced uncertainty in alpha-eigenvalue due to the thermal scattering law data of water.
Tanai, Kenji; Horita, M.*; Dewa, Katsuyuki*; Goke, Mitsuo*
JNC TN8410 2001-026, 116 Pages, 2002/03
Earthquake resistance for the underground structure is higher than the ground structure. Therefore, the case of examining the earthquake resistance of underground structure was little. However, it carries out the research on the aseismic designing method of underground structure, since the tunnel was struck by Hyogo-ken Nanbu Earthquake, and it has obtained a much knowledge. However, an object of the most study was behavior at earthquake of the comparatively shallow underground structure in the alluvial plain board, and it not carry out the examination on behavior at earthquake of underground structure in the deep rock mass. In the meantime, underground disposal facility of the high level radioactive waste constructs in the deep underground, and it carries out the operation in these tunnels. In addition, it has made almost the general process of including from the construction start to the backfilling to be about 60 years (Japan Nuclear Fuel Cycle Development Institute, 1999). During these periods, it is necessary to also consider the earthquake resistance as underground structure from the viewpoint of the safety of facilities. Then, it extracted future problem as one of the improvement of the basis information for the decision of the safety standard and guideline of the country on earthquake-resistant design of the underground disposal facility, while it carried out investigation and arrangement of earthquake-resistant design cases, guidelines and analysis method on existing underground structure, etc.. And, the research item for the earthquake resistance assessment of underground structure as case study of the underground research laboratory.
; ; Yamazaki, Toshihiko; ; ; Kondo, Toshinari*; *
JNC TN8400 2001-030, 99 Pages, 2002/01
There is a great deal of that we build a Base-Isolated building with the quaternary deposit ground. In an atomic energy institution, a study request is strong. When we build a Base-Isolated building with the quaternary deposit ground, evaluation of earthquake vibration of a vertical direction is an important problem. In an atomic energy institution, we design it by big earthquake load, and therefore examination is necessary. And, in this study, we do examination to build a Base-Isolated building with the quaternary deposit ground, we report it about an evaluation method of a design. Furthermore, we report that we estimated pipe laying and machinery to put in a building of Base-lsolated.
;
JNC TN9400 2000-060, 168 Pages, 2000/05
Optimal vertical isolation characteristics were studied for the structural concept of vertical seismic isolation system, which uses a common deck and a set of large coned dish springs. Four kinds of earthquake wave and three kinds of artificial seismic wave were used. The earthquake response analysis of a base isolated building was carried out considering some ground conditions and some vertical vibration characteristics of the building isolator. Floor response and acceleration time history at the vertical isolation level were arranged. Using the acceleration time history as a seismic input, the earthquake response analysis of the vertical isolation system according to single degree of freedom model was carried out. Linear analysis and non-linear analysis were made. ln the linear analysis, vertical isolation frequency was examined within 0.8 to 2.5 Hz, and damping ratio was examined within 2 to 60%. ln the non-linear analysis, it was examined within vertical isolation frequency 0.5 to 5Hz, which depended only on the rigidity of the coned disk spring, rigidity ratio of the damping devise 1 to 20 and yield seismic intensity of the damping devise 0.01 to 0.2. As the optimal vertical isolation characteristics of the system, the criterion of largest relative displacement, maximum acceleration and maximum value of the floor response acceleration between 5 to 12Hz was set, the combination region of the appropriate parameter were examined. ln case of largest relative displacement 50mm, acceleration response magnification of 0.75, floor response magnification of 0.33 were used as a criterion, from the result of the linear analysis, vertical frequency was set at 0.8 to l.2 Hz, and by combining the damping ratio over 20 %, it was proven that appropriate vertical isolation characteristics were obtained. The result of the non-linear analysis showed that the combination of the coned disk spring of vertical frequency 0.8 to 1.0 Hz and the damping element of rigidity ...
Sakurai, Kiyoshi; Yamamoto, Toshihiro; Arakawa, Takuya*; Naito, Yoshitaka
Journal of Nuclear Science and Technology, 34(6), p.544 - 550, 1997/06
Times Cited Count:2 Percentile:23.01(Nuclear Science & Technology)no abstracts in English
Yamamoto, Toshihiro; Sakurai, Kiyoshi; Naito, Yoshitaka; Arakawa, Takuya*
Proc. of Topical Meeting on Criticality Safety Challenges in the Next Decade, 0, p.365 - 370, 1997/00
no abstracts in English
JAERI-M 8672, 89 Pages, 1980/02
no abstracts in English
Iwamoto, Hiroki; Nishihara, Kenji; Yagi, Takahiro*; Pyeon, C. H.*
no journal, ,
no abstracts in English
Katano, Ryota; Tsujimoto, Kazufumi
no journal, ,
no abstracts in English
Yamaguchi, Hibiki*; Endo, Tomohiro*; Yamamoto, Akio*; Tada, Kenichi
no journal, ,
The numerical solution of the alpha eigenvalue is obtained by the inverse power iteration method. This method requires a large number of iterations to calculate the alpha eigenvalue. This study developed the acceleration method using the DMD method to reduce the calculation time of the alpha eigenvalue calculation and validated the developed method.
Katano, Ryota
no journal, ,
To investigate the condition where the subcriticality can be accurately measured by the pulsed neutron source experiment, we have calculated the average number of the generation of the detected neutron when defining the generation as a period during which a fission neutron causes a next fission. The results revealed that the linearity between the average number of the generation and time is important for the accurate subcriticality measurement.
Harada, Yoshinari*; Yamaguchi, Hibiki*; Endo, Tomohiro*; Yamamoto, Akio*; Tada, Kenichi
no journal, ,
The data assimilation using the prompt neutron decay constant was performed to reduce the uncertainty in nuclear calculations due to the thermal neutron scattering law (TSL) for light water. The uncertainty in the effective multiplication factor due to TSL for light water can be reduced using the bias factor method based on the deterministic sampling method when there is a strong correlation between nuclear properties through TSL for light water.